Summary
CVE-2026-0993 is a pre-authentication buffer overflow (CWE-120) in the embedded HTTP server of the SODOLA SL902-SWTGW124AS managed switch. A remote, unauthenticated attacker can send a crafted HTTP POST request to crash the device and cause a denial of service. The CVSS v4.0 base score is 8.7 (High).
Technical details
- Root cause: The multipart/form-data boundary parser copies the boundary value without checking its size (CWE-120, Buffer Copy without Checking Size of Input).
- Trigger conditions: An HTTP POST request with a
Content-Type: multipart/form-dataheader whose boundary parameter is oversized. The researcher reports that a boundary of roughly 1440 bytes or more is enough to trigger the crash. - Attack vector: Network. No authentication or user interaction is required. The researcher reports that the vulnerable endpoints (
/fwug.cgi,/login.cgi,/login_ft.cgi) are reachable before login. - Impact: The management interface stops responding, the switch no longer answers ping, and all port-to-port traffic forwarding halts. The researcher measured this at about 11–13 seconds per event. An attacker can repeat the request to prolong the disruption. No confidentiality or integrity impact is documented.
Affected software
- SODOLA SL902-SWTGW124AS firmware prior to V200.2.12. The researcher confirmed V200.2.4 and V200.2.10 as vulnerable.
- The CVE record lists "200.2.12 and earlier" as affected, which conflicts with its own fixed-version statement. The researcher reports that V200.2.12 fixes the issue.
Severity
- CVSS v4.0: 8.7 (High) –
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N - CVSS v3.1 (as listed in the CVE record): 7.5 (High) –
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Mitigation and recommended actions
- Immediate: Upgrade to firmware V200.2.12 or later. The researcher notes the vendor acknowledged the issue on August 5, 2026 and supplied a corrected build, but that V200.2.12 had not yet appeared on the public download page when they wrote up the issue. Contact SODOLA to obtain the build.
- If you cannot patch: Restrict access to the switch’s web management interface with ACLs or a dedicated management VLAN, and do not expose it to untrusted networks or the internet. Changing passwords does not help, because the flaw is triggered before authentication.