Summary
CVE-2026-102255 is a maximum-severity, pre-authentication Server-Side Request Forgery (SSRF) vulnerability in the Appliance WorkPlace interface of SonicWall’s SMA1000 series secure remote access gateways. An unauthenticated remote attacker can abuse an unintended alternate access path to force the appliance into issuing requests on its behalf, reaching internal functionality and performing unauthorized operations. SonicWall rates this issue CVSS v3.1 10.0 (Critical), and while there is no evidence of in-the-wild exploitation at the time of disclosure, SMA1000 appliances have historically been targeted with weaponized zero-days.
Technical details
- Root cause: An unintended alternate access path exists in the Appliance WorkPlace interface, allowing the component to be reached in a manner not intended by the normal authentication flow (CWE-918 SSRF, CWE-441 Confused Deputy).
- Trigger conditions: No authentication, user interaction, or special privileges are required; the flaw is reachable directly over the network.
- Attack vector: Network-based (AV:N), low attack complexity (AC:L), no privileges required (PR:N), no user interaction (UI:N).
- Impact: A successful exploit allows the appliance to be directed into issuing requests on the attacker’s behalf, enabling access to internal functionality/systems and unauthorized operations, with full loss of confidentiality, integrity, and availability (scope changed).
Affected software
- SonicWall SMA1000 series (physical and virtual appliances: 6210, 7210, 8200v)
- Firmware 12.4.3-03526 (platform-hotfix) and earlier
- Firmware 12.5.0-02952 (platform-hotfix) and earlier
- Not affected: SonicWall firewall SSL-VPN and the SMA 100 Series product line
Severity
- CVSS v3.1 Base Score: 10.0 (Critical)
- Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
Mitigation and recommended actions
- Immediate: Upgrade SMA1000 firmware to version 12.4.3-03670 or higher, or 12.5.0-03082 or higher.
- If immediate patching is not possible: Restrict and monitor internet exposure of the SMA1000 Appliance WorkPlace interface, review access logs for anomalous or unauthorized request patterns, and prioritize patching given the critical severity and the appliance’s role as an internet-facing remote access gateway.