Summary
CVE-2026-102764 is a critical improper origin validation flaw (CWE-290, authentication bypass by spoofing) in an internal messaging component of BeyondTrust Remote Support. A remote, unauthenticated attacker can perform file operations on the appliance. The CVE record gives it a CVSS score of 9.3 (Critical). BeyondTrust’s vendor blog post on the issue describes exploitation by a threat actor.
Technical details
- Root cause: Internal components did not adequately validate the origin of the messages they received (CWE-290; CAPEC-194).
- Trigger conditions: "Under the right conditions", per the CVE description. No authentication or user interaction is required.
- Attack vector: Network, low complexity.
- Impact: An attacker can perform file operations on the appliance. The vector rates confidentiality, integrity and availability impact as High.
- Exploitation: BeyondTrust’s blog post says the flaw was exploited by a China-nexus actor it names ARMORY CASTLE. The post also says the attacker deletes local appliance logs. BeyondTrust is withholding technical details while self-hosted appliances are still being patched.
- Related product: Privileged Remote Access shares the affected code. BeyondTrust patched it as a precaution and has not identified a confirmed exploitation method.
Affected software
- BeyondTrust Remote Support: all versions through 26.2.3 (per the CVE record).
- The BT26-05-RS patch covers self-hosted versions 24.3.1 through 26.2.3. Older instances must first upgrade to a supported version.
- Self-hosted appliances are exposed until they are patched. BeyondTrust patched SaaS instances automatically.
Severity
- CVSS v4.0 base score 9.3 (Critical):
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N - The CVE record provides a CVSS v4.0 vector only. A v3.1 vector was not found.
Mitigation and recommended actions
- Immediate: Self-hosted customers should apply the BT26-05-RS patch from advisory BT26-05. The advisory does not list a fixed version number. SaaS customers need no action.
- If you suspect exploitation, rotate every credential the appliance stored or injected.
- Restrict access to the administrative interface to trusted networks.
- Forward appliance logs to a SIEM in near real time, because local logs may be deleted.
- Hunt for suspicious administrative sessions, for example from residential or VPN addresses.