Summary
CVE-2026-108918 is a command injection vulnerability (CWE-77 / CWE-74) in the Edimax BR-6208AC router, firmware version 1.32. It is rated Critical (CVSS 10.0) and can be reached over the network without authentication or user interaction, according to the published scoring.
Technical details
- Root cause: Improper neutralization of special elements in a command. The
readE2Pargument handled by the/goform/formWlanMPendpoint is not safely handled, which leads to command injection. - Trigger conditions: A crafted request to
/goform/formWlanMPthat manipulates thereadE2Pparameter. The CVE record does not identify the specific internal function. - Attack vector: Network. The CVSS vector indicates no privileges required and low attack complexity.
- Impact: Arbitrary command execution on the device, with high impact to confidentiality, integrity and availability and a changed scope (S:C) in the CVSS v3.1 vector.
- Exploit status: A public exploit/write-up is referenced in the CVE record (GitHub repository fizz-is-on-the-way/Iot_vuls). The CVSS vector reflects proof-of-concept exploit maturity (E:P). The vulnerability was reported via VulDB (VDB-416730).
Affected software
- Edimax BR-6208AC, firmware version 1.32
Severity
- CVSS v3.1 base score: 10.0 (Critical)
- Vector:
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H - A CVSS v4.0 score of 10.0 is also published.
Mitigation and recommended actions
- Immediate: No vendor patch or fixed firmware version was identified in the sources reviewed. Check Edimax’s support site for updated firmware for the BR-6208AC and apply it if one becomes available.
- If no patch is available:
- Do not expose the router’s web management interface to the internet. Restrict it to trusted internal management networks.
- Block external access to
/goform/formWlanMPwhere filtering is possible. - Monitor for unexpected requests to
/goform/endpoints and for unusual outbound connections from the device. - Consider replacing the device if it is internet-exposed and no fix is released.